Please use this identifier to cite or link to this item: https://hdl.handle.net/1/1257
Full metadata record
DC FieldValueLanguage
dc.contributor.authorBack, Michael-
dc.contributor.authorEade, Thomas-
dc.contributor.otherClifford, S.-
dc.contributor.otherWheeler, H.-
dc.date.accessioned2019-01-14T04:54:59Zen
dc.date.available2019-01-14T04:54:59Zen
dc.date.issued2013-12-
dc.identifier.citationVolume 4, Issue 11, pp. 18 - 24en
dc.identifier.issn2151-1934en
dc.identifier.urihttps://elibrary.cclhd.health.nsw.gov.au/cclhdjspui/handle/1/1257en
dc.description.abstractAims: The EORTC-NCI study investigating the addition of temozolomide trial to standard radiation therapy has demonstrated improved duration of survival in patients with Glioblastoma multiforme (GBM). With longer survival duration, there is the potential for latent RT morbidity, not previously seen in historical patients. This study evaluates the potential dosimetric advantages of utilising IMRT over 3D-conformal RT in such patients. Methods: 10 consecutive patients with GBM formally screened for a clinical study over a two-month period were planned and treated with IMRT utilising daily on-board imaging (OBI). The EORTC protocol dosimetric criteria and constraints were used in target delineation and planning. For each patient, a 3DCRT plan was also produced. Endpoints for dosimetric evaluation analysed related to tumour dose: mean PTV60 dose (mPTV60Dose), Conformity Index (CI); and normal tissue dose: mean normal brain do se (mBrainDose) and V4 0 Brain (Brainv40). IGRT endpoints w ere the median isocentre shifts r equired in 3 axes measured in one direction. The variation between the IMRT and 3DCRT dosimetric endpoints was examined using Wilcoxon analysis. Results: The 10 patients had tumours located in temporal (3), parietal (3), occipital (2) and callosal (2) regions. The median PTV and normal brain volumes were 308.1 cm3 and 1077.5 cm3 respectively. The IMRT dosimetry was significantly improved in all endpoints specifically CI (p = 0.002), mPTV60Dose (p = 0.004), mBrainDose (p = 0.002) and Brainv40 (p = 0.019). OBI directed isocentre measurements in the patient group were available for 230 treatments. The median shifts (and 95% C.I.s) were 0.1 cm vertical (0.1 - 0.2), 0.1 cm longitudinal (0.1 - 0.2) and 0.2 cm lateral ( 0.2 - 0.2). At a minimum foll ow-up of 2 years’ post diagnosis, the median survival of the group is 18.0 months (95% CI: 13.4 - 22.6 months). Conclusion: IMRT for GBM produces significant dosimetric advantages in relation to planning target volume and normal tissue dose compared with 3D conformal plans. The data also confirm the accuracy of IMRT technique for CNS with IGRT delivery utilising OBI demonstrating minimal deviation from planned to treated isocentre.en
dc.subjectCanceren
dc.subjectRadiotherapyen
dc.subjectDrug Therapyen
dc.titleDosimetric Improvements Utilising Intensity Modulated Radiation Therapy for Patients with Glioblastoma Multiformeen
dc.typeJournal Articleen
dc.identifier.doi10.4236/jct.2013.411A003en
dc.identifier.journaltitleJournal of Cancer Therapyen
dc.relation.orcidhttp://orcid.org/0000-0003-2363-8333en
dc.originaltypeTexten
item.grantfulltextnone-
item.fulltextNo Fulltext-
item.openairecristypehttp://purl.org/coar/resource_type/c_18cf-
item.openairetypeJournal Article-
item.cerifentitytypePublications-
crisitem.author.deptRadiation Oncology-
Appears in Collections:Oncology / Cancer
Radiology
Show simple item record

Page view(s)

44
checked on Nov 24, 2024

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.