dc.contributor.authorMoloney, Jayson-
dc.contributor.otherHiscock, R.-
dc.contributor.otherNguyen, M.H.-
dc.date.accessioned2019-07-09T23:42:43Zen
dc.date.available2019-07-09T23:42:43Zen
dc.date.issued2019-07-
dc.identifier.citation89(11):1462-1465en
dc.identifier.issn1445-1433en
dc.identifier.urihttps://elibrary.cclhd.health.nsw.gov.au/cclhdjspui/handle/1/1551en
dc.description.abstractBACKGROUND: The efficacy of rubber band ligation of haemorrhoids relies on the load generated on haemorrhoidal tissue by bands as they return to their preformed shape after being deployed. 'Preloaded' haemorrhoid banding devices are widely available, but the effect of the resultant prolonged stretch on bands while stored in this manner has never been examined by comparing these to manually loaded devices, which are stretch immediately prior to being deployed. A difference could have clinical relevance, potentially resulting in a higher rate of clinical failure. The present study aimed to investigate any difference in load generated by preloaded versus manually loaded devices. METHODS: A preloaded and a manually loaded device were selected for comparison. Each type was measured on a testing rig. The device type, load generated by each band and the time to expiry were recorded. RESULTS: A total of 137 haemorrhoid bands were tested: 66 preloaded and 71 manually loaded. There was a statistically significant overall reduction in load generated by preloaded versus manually loaded devices (284.0 versus 272.1 g, mean difference -11.9 g, 95% confidence interval -17.5 to -6.3 g, P = 0.0001). Adjusted for time, the load generated by preloaded bands fell 3.7 g (95% confidence interval 2.7-4.8, P < 0.001) for each month closer to the expiry date. CONCLUSIONS: The load generated by haemorrhoid bands from preloaded devices is lower and deteriorates significantly towards their expiry date compared with bands from manually loaded devices. This is mostly likely due to their storage in a stretched state. This should be considered by clinicians when using haemorrhoid banding devices.en
dc.description.sponsorshipColorectal Surgeryen
dc.subjectGeneral Surgeryen
dc.subjectGastrointestinal Tracten
dc.titleInferior load generated by preloaded versus manually loaded haemorrhoid banding devices: the effect of 'creep relaxation'en
dc.typeJournal Articleen
dc.identifier.doi10.1111/ans.15325en
dc.description.pubmedurihttps://www.ncbi.nlm.nih.gov/pubmed/31271248en
dc.description.affiliatesCentral Coast Local Health Districten
dc.description.affiliatesGosford Hospitalen
dc.identifier.journaltitleAnz Journal of Surgeryen
dc.originaltypeTexten
item.grantfulltextnone-
item.fulltextNo Fulltext-
item.openairecristypehttp://purl.org/coar/resource_type/c_18cf-
item.openairetypeJournal Article-
item.cerifentitytypePublications-
Appears in Collections:Health Service Research
Show simple item record

Page view(s)

58
checked on Apr 26, 2025

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.