Please use this identifier to cite or link to this item:
https://hdl.handle.net/1/2084
Title: | Evaluation of a radiotherapy protocol based on INT0116 for completely resected gastric adenocarcinoma | Authors: | Back, Michael ;Chung, H.T.;Shakespeare, T.P.;Wynne, C.J.;Lu, J.J.;Mukherjee, R.K. | Issue Date: | Aug-2004 | Source: | Volume 59, Issue 5, pp. 1446 - 1453 | Journal title: | Evaluation of a radiotherapy protocol based on INT0116 for completely resected gastric adenocarcinoma | Abstract: | Purpose: With the results of the INT0116 study, adjuvant radiochemotherapy has become the standard treatment after complete resection of gastric adenocarcinoma. However, the implementation of radiotherapy (RT) remains a concern. In response, consensus guidelines on RT technique have been published. Our objective was to measure the inter- and intraclinician variability in RT field delineation using conventional two- (2D) and three-dimensional (3D) techniques. Methods and materials: Between 1999 and 2003, five radiation oncologists (ROs) treated 45 patients with completely resected, gastric adenocarcinoma using postoperative radiochemotherapy (INT0116). Two cases were included in this study (Patient 1 had cardia and Patient 2 had antral disease). Standardized vignettes (with surgical and pathologic findings) and preoperative and postoperative imaging for each case were developed. Each RO designed AP-PA fields for each patient (2D planning) on two separate occasions. This was repeated using a 3D planning technique. Results: Patient 1 had a mean field area of 250.2 cm(2) (SD 12.0) and 227.9 cm(2) (SD 26.5) using 2D and 3D planning, respectively (p = 0.03). The mean clinical target volume (CTV) volume was 468.3 cm(3) (SD 65.9). Patient 1 had a significantly greater inter- than intra-RO variation for the field area designed with 3D planning; however, no difference occurred with 2D planning or CTV contouring. Patient 2 had a mean field area of 234.8 cm(2) (SD 33.1) and 226.8 cm(2) (SD 19.3) using 2D and 3D planning, respectively (p = 0.5). The mean CTV was 729.4 cm(3) (SD 67.3). For Patient 2, the inter-RO variability was significantly greater than the intra-RO variability for the field area using both 2D and 3D planning, and no difference was seen for the CTV. Composite beam's-eye-view plots revealed that the superior, inferior, and right lateral borders proved to be most contentious. Conclusion: Despite published guidelines and a departmental protocol, significant variations in the RT field areas were seen among ROs for both 2D and 3D planning. However, in general, CTV contouring was reproducible. Because 3D-RT hinges on accurate target identification, caution should be exercised before migrating to 3D planning for postoperative gastric cancer. | URI: | https://elibrary.cclhd.health.nsw.gov.au/cclhdjspui/handle/1/2084 | DOI: | 10.1016/j.ijrobp.2004.01.001 | Pubmed: | https://pubmed.ncbi.nlm.nih.gov/15275731/ | Publicaton type: | Journal Article | Keywords: | Cancer Radiotherapy Drug Therapy |
Appears in Collections: | Oncology / Cancer Radiology |
Show full item record
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.